EasyManua.ls Logo

Tektronix 2236 - TRIGGER CONTROLS

Tektronix 2236
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preparation
For
Use
-
2236
Operators
VAR
HOLOOFF
B
-
Horizontal
deflection
is
provided
by
the
B
Sweep
generator
at
a
sweep
speed
determined
by
the
B
SEC
/
DIV
switch
setting
.
The
start
of
the
B
Sweep
is
delayed
from
the
start
of
the
A
Sweep
by
a
time
determined
by
the
settings
of
both
the
A
SEC
/
DIV
switch
and
the
B
DELAY
TIME
POSI
TION
control
.
Gated
frequency
,
period
,
width
,
and
totalize
measurements
are
made
on
the
B
Trigger
signal
.
Reno
2998
L
NOAM
MAX
28
B
TRIGGER
INT
LEVELD
SOURCE
ONL
34
SLOPE
IN
25
OUT
33
A
TRIGGER
SGL
SWP
PPAUTO
,
NOAM
TV
LINE
RESET
LIVFIELD
READY
TRIG'D
LEVEL
26
22
POSITION
Control
Horizontally
positions
both
the
A
Sweep
and
the
B
Sweep
displays
and
horizontally
po
sitions
X
-
axis
in
the
X
-
Y
mode
.
SLOPE
28
IN
:
OUT
:
30
A
&
B
INT
CH1
A
SOURCE
INT
A
EXT
COUPLING
AC
u
VERT
MODE
27
LINE
DC
23
A
/
B
SWP
SEP
Control
-
Vertically
positions
the
B
Sweep
trace
with
respect
to
the
A
Sweep
trace
when
ALT
HORIZONTAL
MODE
is
selected
.
CH
2
{
X1
OC
32
-10
EXT
INPUT
31
1
IM2
22pF
100mV
/
DIV
400V
pk
29
4205-06
Fig
.
2-6
.
Trigger
controls
,
connector
,
and
indicator
.
24
B
DELAY
TIME
POSITION
Control
Selects
the
amount
of
delay
time
between
the
start
of
the
A
Sweep
and
the
start
of
the
B
Sweep
.
In
A
TIME
mode
,
the
B
DELAY
TIME
POSITION
control
oper
ates
in
conjunction
with
the
A
TIME
POSITION
con
trol
.
The
B
DELAY
TIME
POSITION
control
moves
both
intensified
zones
(
reference
and
comparisons
)
,
while
the
A
TIME
POSITION
control
moves
only
one
intensified
zone
(
time
-
measurement
point
)
.
Time
dif
ference
between
the
start
of
the
two
intensified
zones
is
displayed
on
the
readout
.
In
DLY
TIME
mode
,
only
one
intensified
zone
is
displayed
which
is
controlled
by
the
B
DELAY
TIME
POSITION
control
.
The
time
dif
ference
between
the
start
of
the
A
Sweep
and
the
start
of
the
intensified
zone
is
displayed
on
the
readout
.
ال
displaying
and
photographing
either
nonrepetitive
signals
or
signals
that
cause
unstable
conventional
displays
(
e.g.
,
signals
that
vary
in
amplitude
,
shape
,
or
time
)
.
It
also
allows
the
gated
totalize
function
to
acquire
signals
over
just
one
gate
inter
val
for
events
counting
.
u
TRIGGER
Refer
to
Figure
2-6
for
location
of
item
25
through
34
.
P
-
P
AUTO
-
TV
LINE
-
Permits
triggering
on
wave
forms
having
repetition
rates
of
at
least
20
Hz
and
television
lines
.
Sweep
free
-
runs
in
the
absence
of
an
adequate
trigger
signal
or
when
the
repetition
rate
is
below
20
Hz
.
The
range
of
the
A
TRIGGER
LEVEL
control
is
restricted
to
the
peak
-
to
-
peak
range
of
the
trigger
signal
.
u
25
A
TRIGGER
Mode
Switches
-
Three
section
switch
that
determines
the
trigger
mode
for
the
A
Sweep
.
NORM
-
Sweep
is
initiated
when
an
adequate
trig
ger
signal
is
applied
.
In
the
absence
of
a
trigger
signal
,
no
baseline
trace
will
be
present
.
SGL
SWP
RESET
-
Press
in
the
spring
-
return
but
ton
momentarily
to
arm
the
A
Sweep
circuit
or
a
single
-
sweep
display
or
to
reset
the
CTM
when
in
TOTALIZE
mode
.
In
CH
1
V
mode
,
pressing
the
SGL
SWP
RESET
button
will
enter
or
cancel
rela
tive
reference
mode
.
TV
FIELD
--
Press
in
both
P
-
P
AUTO
and
NORM
buttons
.
Permits
triggering
on
television
field
sig
.
nals
.
A
TRIGGER
LEVEL
control
range
and
auto
baseline
are
the
same
as
in
P
-
P
AUTO
.
In
single
-
sweep
display
mode
,
the
trigger
system
operates
the
same
as
NORM
,
except
only
one
sweep
is
displayed
for
each
trigger
signal
.
Another
sweep
cannot
be
displayed
until
the
SGL
SWP
RE
SET
button
is
momentarily
pressed
in
again
to
re
set
the
A
Sweep
circuit
.
This
mode
is
useful
for
26
TRIG'D
-
READY
Indicator
-
LED
illuminates
when
ei
ther
P
-
P
AUTO
or
NORM
Trigger
Mode
is
selected
,
when
the
A
Sweep
has
been
triggered
(
TRIG'D
)
.
When
SGL
SWP
RESET
button
is
momentarily
C
2-6

Table of Contents

Related product manuals