EasyManua.ls Logo

Tektronix 2236 - OPERATORS ADJUSTMENTS; Introduction to Adjustments; Baseline Trace Setup; Trace Rotation Adjustment

Tektronix 2236
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Operators
Familiarization
-
2236
Operators
OPERATOR'S
ADJUSTMENTS
INTRODUCTION
B
TRIGGER
C
SLOPE
LEVEL
OUT
:
Fully
clockwise
To
verify
the
operation
and
accuracy
of
your
instrument
before
making
measurements
,
perform
the
following
adjustment
procedures
.
If
adjustments
are
required
beyond
the
scope
of
the
operators's
adjustments
,
refer
the
instrument
to
a
qualified
service
technician
.
A
TRIGGER
C
Before
proceeding
with
these
instructions
,
refer
to
Preparation
for
Use
"
(
Section
2
)
.
VAR
HOLDOFF
Mode
SLOPE
LEVEL
A
&
B
INT
A
SOURCE
A
EXT
COUPLING
NORM
P
-
P
AUTO
OUT
:
2
Midrange
VERT
MODE
INT
AC
1
Verify
that
the
POWER
switch
is
OFF
(
push
button
out
)
,
then
plug
the
power
cord
into
the
power
-
source
outlet
.
CTM
U
Midrange
All
buttons
out
If
indications
specified
in
these
procedures
cannot
be
obtained
,
refer
the
instrument
to
a
qualified
service
technician
A
TIME
POSITION
Function
Select
UPPER
FUNCTIONS
LOWER
FUNCTIONS
OUT
BASELINE
TRACE
2.
Press
in
the
POWER
switch
button
(
ON
)
and
allow
the
instrument
to
warm
up
(
20
minutes
is
recommended
for
maximum
accuracy
)
.
ܐ
First
obtain
a
baseline
trace
,
using
the
following
procedure
.
wy
3.
Adjust
the
A
INTENSITY
control
for
desired
display
brightness
.
1.
Preset
the
instrument
front
-
panel
controls
as
follows
:
Display
4.
Adjust
the
Vertical
and
Horizontal
POSITION
controls
as
needed
to
center
the
trace
on
the
screen
.
A
and
B
INTENSITY
FOCUS
Fully
counterclockwise
Midrange
C
C
Vertical
(
Both
Channels
)
TRACE
ROTATION
POSITION
VERTICAL
MODE
BW
LIMIT
VOLTS
/
DIV
VOLTS
/
DIV
Variable
INVERT
Input
Coupling
Midrange
CH
1
Off
(
button
out
)
50
m
CAL
detent
Off
(
button
out
)
AC
Normally
,
the
resulting
trace
will
be
parallel
to
the
center
horizontal
graticule
line
,
and
the
Trace
Rotation
adjustment
should
not
be
required
.
If
adjustment
is
needed
,
perform
the
following
procedure
:
C
C
C
1.
Preset
instrument
controls
and
obtain
a
baseline
trace
.
Horizontal
2.
Use
the
Channel
1
POSITION
control
to
move
the
baseline
trace
to
the
center
horizontal
graticule
line
.
A
/
B
SWP
SEP
Off
midrange
POSITION
Midrange
HORIZONTAL
MODE
А
A
and
B
SEC
/
DIV
0.5
ms
SEC
/
DIV
Variable
CAL
detent
X10
Magnifier
Off
(
knob
in
)
B
DELAY
TIME
POSITION
Fully
counterclockwise
C
3.
If
the
resulting
trace
is
not
parallel
to
the
center
hori
zontal
graticule
line
,
use
small
flat
-
bit
screwdriver
to
adjust
the
TRACE
ROTATION
control
and
align
the
trace
with
the
center
horizontal
graticule
line
.
L
3-4

Table of Contents