Operators
Familiarization
-
2236
Operators
CTM
MEASUREMENT
CONSIDERATIONS
precharging
network
.
This
network
allows
the
input
coupling
capacitor
to
charge
to
the
average
dc
-
voltage
level
of
the
signal
applied
to
the
probe
.
Thus
any
large
voltage
transients
that
may
accidentally
be
generated
will
not
be
applied
to
the
amplifier
input
when
the
input
Coupling
switch
is
moved
from
GND
to
AC
.
The
precharging
network
also
provides
a
measure
of
protection
to
the
external
circuitry
by
reducing
the
current
levels
that
can
be
drawn
from
the
ex
ternal
circuitry
during
capacitor
charging
.
Nongated
measurements
are
performed
from
the
A
Trig
ger
system
on
signals
selected
by
the
A
Trigger
source
switches
.
Signals
may
be
applied
through
the
CH
1
input
,
CH
2
,
or
the
EXT
INPUT
connectors
.
Nongated
measure
ments
may
also
be
performed
on
the
instrument
power
source
by
setting
the
A
SOURCE
switch
to
LINE
position
.
The
A
TRIGGER
LEVEL
control
,
A
TRIGGER
Mode
,
A
TRIGGER
SLOPE
,
A
&
B
INT
,
A
SOURCE
,
A
EXT
COU
PLING
,
and
BW
LIMIT
switches
are
effective
in
conditioning
the
input
signal
.
The
following
procedure
should
be
used
whenever
the
probe
tip
is
connected
to
a
signal
source
having
a
different
dc
level
than
that
previously
applied
,
especially
if
the
dc
level
difference
is
more
than
10
times
the
VOLTS
/
DIV
switch
setting
:
1.
Set
the
Input
Coupling
switch
to
GND
.
Trigger
status
messages
(
no
A
trig
and
no
b
trig
"
)
are
not
displayed
in
any
mode
of
the
width
function
so
that
mea
surement
results
can
be
displayed
indefinitely
.
This
allows
single
pulse
measurements
.
C
U
2.
Insert
the
probe
tip
into
the
oscilloscope
GND
connec
tor
and
wait
several
seconds
for
the
input
coupling
capacitor
to
discharge
.
3.
Connect
the
probe
tip
to
the
signal
source
and
wait
several
seconds
for
the
input
coupling
capacitor
to
charge
.
Gated
measurements
are
performed
from
the
B
Trigger
system
on
input
signals
being
applied
to
either
CH
1
,
or
CH
2
input
connectors
.
The
gate
interval
(
set
by
adjusting
the
intensified
zone
with
the
B
DELAY
TIME
POSITION
control
and
the
B
SEC
/
DIV
switch
)
must
be
shorter
than
the
A
Sweep
duration
,
such
that
the
intensified
zone
ends
before
A
Sweep
ends
.
The
A
TRIGGER
A
&
B
INT
switch
and
the
B
TRIGGER
LEVEL
control
and
SLOPE
switch
are
effective
in
conditioning
the
input
signal
.
4.
Set
the
Input
Coupling
switch
to
AC
.
The
display
will
remain
on
the
screen
,
and
the
ac
component
of
the
signal
can
be
measured
in
the
normal
manner
.
بال
POWER
-
UP
CHECKS
Noise
may
be
coupled
to
the
A
and
B
Trigger
circuits
along
with
the
signal
to
be
measured
.
Noise
may
originate
from
the
operating
environment
,
the
signal
source
,
or
by
improper
connections
.
If
the
noise
is
of
sufficient
amplitude
,
it
can
result
in
inaccurate
measurements
due
to
false
trig
gering
.
The
2236
has
a
20
MHz
Bandwidth
Limiter
that
is
helpful
in
removing
or
reducing
the
noise
in
the
A
and
B
Trigger
systems
.
11
21
The
Counter
,
Timer
,
and
Multimeter
(
CTM
)
contains
Power
-
Up
Checks
that
are
performed
each
time
the
instru
ment
is
turned
on
.
These
checks
consists
of
ROM
checksum
,
counter
,
and
DMM
in
this
order
.
Each
of
these
checks
must
pass
before
proceeding
to
the
next
check
.
If
a
check
fails
,
an
error
message
will
appear
in
the
readout
(
see
Table
3-1
)
.
Refer
the
error
message
to
qualified
service
personnel
.
Channel
1
volts
measurements
should
be
made
with
the
signal
fully
displayed
within
the
graticule
area
through
the
appropriate
use
of
the
CH
1
VOLTS
/
DIV
switch
and
CH
1
VOLTS
/
DIV
Variable
control
.
This
prevents
the
Channel
1
input
circuit
from
being
overdriven
and
distorting
the
voltage
measurements
.
C
C
TABLE
3-1
Power
-
Up
Checks
U
STATUS
AND
ERROR
MESSAGES
Check
Error
Message
The
Counter
,
Timer
,
and
Multimeter
(
CTM
)
system
will
display
several
types
of
status
and
error
messages
on
the
readout
.
C
ROM
Checksum
FAIL
-
ro
Counter
FAIL
-
ctr
Control
button
Error
-
When
the
buttons
are
in
an
ille
gal
mode
,
the
readout
will
display
Control
button
Er
ror
"
by
scrolling
it
across
the
readout
.
The
error
message
will
repeat
itself
until
a
correction
is
made
.
DMM
FAIL
-
d
Common
3-2

Table of Contents