Performance Characteristics
Table 6-2 (cont)
Characteristics
Performance Requirements
CONTINUITY
Response Time
Threshold Resistance
Approximately 0.1 second.
iO it ±i u.
TEMPERATURE
Accuracy
-f 18°C to +28°C Ambient
Temperature
-15°C to +18°C and + 28°C
to +55°C Ambient Temperature
Probe Tip Measurement Range
Resolution
±(2%
of reading +
1.5°C).
±(2%
of reading +■ 2.0
°C).
-62°C to +230°C in one range.
0.1°Cor0.1°F.
ADDITIONAL CHARACTERISTICS
Warmup time to Meet Electrical
Specification
Maximum Voltage between Inputs
from either Input to Ground
DC to 20 kHz
Above 20 kHz
45 minutes.
500 V rms; 700 V peak.
10
7
V*Hz.
NOTE
For AMPS modes, maximum voltage between inputs is limited by maximum
input
current.
2465B/2455B/2445B Operators
6-25