Commands Listed in Alphabetical Order
Group
Horizontal
Syntax
HORizontal:MAIn:TOLPoint?
Examples
HORIZONTAL:MAIN:TOLPOINT? might return HORIZONTAL:MAIN:TOLPOINT
40.3000000000E–009
, indicating that the time interval between the trigger
point and the last point in the Main timebase record is 40.3 ns.
HORizontal:MATH<x>:MAGnify<x>:POSition? (Query Only)
This query only command returns the horizontal position of the specied math
waveform using the specied Mag timebase. The math waveform i s specied by x,
which can be 1 through 8; the Mag timebase is specied by x, which can be 1 or 2 .
Group
Horizontal
Syntax
HORizontal:MATH<x>:MAGnify <x>:POSition?
Examples
HORIZONTAL:MATH1:MAG2:POSI TION? might return
HORIZONTAL:MATH
1:MAGNIFY2:POSITION 19.0000000000E–0 09
,
indicating that the horizontal position of the Math 2 waveform using the MAG2
timebase is set to the minimum time o f 19 ns.