Commands Listed in Alphabetical Order
HORizontal:R
EF<x>:MAIn:REFPoint? (Query Only)
This query only command returns the horizontal reference point of the specified
reference waveform using the Main timebase. The reference waveform is
specified by x
, which can be 1 through 8.
Group
Horizontal
Syntax
HORizontal:REF<x>:MAIn:RE FPoint?
Related Commands
HORizontal:REF<x>:MAIn:SCAle?
Examples
HORIZONTAL:REF1:MAIN:REFP OINT? might return
HORIZONTAL:REF1:MAIN:REFP OINT 5.00000000000E–001, indicating that
the horizontal reference point of Reference 1 waveform using th
e Main timebase
is set to 0.5 (50%), which is the default.
HORizontal:REF<x>:MAIn:RESolution? (Query Only)
This query only c ommand returns the current resolution per sample of the
specified reference waveform using the Main timebase. The reference waveform
is specified by x, which can be 1 through 8. The resolution value is the same as the
value displayed in the Resolution fieldintheTimebasesect
ion of the Horizontal
Setup dialog box. The resolution is determined by the scale and recordlength
values of the reference waveform. Resolution is displayed in horizontal units,
typically time.
Group
Horizontal
Syntax
HORizontal:REF<x>:MAIn:RE Solution?
Related Commands
HORizontal:REF<x>:MAIn:SCAle?, HORizontal:REF<x>:MAIn:
RECordlength?
Examples
HORIZONTAL:REF7:MAIN:RESO LUTION? might return
HORIZONTAL:REF7:MAIN:RESO LUTION 10.00000000000E–01 2,
indicating that the Reference 7 waveform resolution using the Main timebase
is 10 ps.
2-190 DSA/CSA/TDS8X00/B Series Programmer Manual