Commands Listed in Alphabetical Order
MEASUrement:
MEAS<x>:REFLevel<x>:ABSolute:HIGH
This command sets or queries the high reference level in absolute user units for
the specied measurement. The measurement slot is specied by x, which can be
1 through 8. T
he reference level source is specied by x, which can only be 1 for
this measurement (or defaults to 1 if not specied).
This absolu
te value is used as the high reference level when
MEASUrement:MEAS<x>:REFLevel<x>:METHod is set to ABSolute. Sending
this command is equivalent to selecting the RefLevel tab in the Measurement
Setup dialog box, selecting Absolute in the Reference Level Calc Method section,
and then entering an absolute value for Hi in the Reference section.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:REFLe vel<x>:ABSolute:HIGH <NR3 >
MEASUrement:MEAS<x>:REFLe vel<x>:ABSolute:HIGH?
Related Commands
MEASUrement:MEAS<x>:REFLevel<x>:METHod
Arguments
NR3 is the high reference level in absolute user units. The default is 0 V.
Examples
MEASUREMENT:MEAS3:REFLEVE L1:ABSOLUTE:HIGH 2.0E–1 sets the high
reference level for Measurement 3 to 200 mV.
MEASUREMENT:MEAS2:REFLEVE L1:ABSOLUTE:HIGH? might return
MEASUREMENT:MEAS2:REFLEVE L1:ABSOLUTE:HIGH 9.00000000000E –2,
indicating that the high reference level for Measurement 2 to is set to 90 mV.
MEASUrement:MEAS<x>:REFLevel<x>:ABSolute:LOW
This command sets or queries the low reference level in absolute user units for
the specied measurement. The measurement slot is specied by x, which can be
1 through 8. The reference level source is specied x, which can only be 1 for
this measurement (or defaults to 1 if not specied).
This absolute value is used as the low reference level when
MEASUrement:MEAS<x>:REFLevel<x>:METHod is set to ABSolute. Sending
this command is equivalent to selecting Absolute in the Reference Level Calc
Method section of the RefLevel dialog and then entering an absolute valu e for
Low in the Reference section of the Measurement Setup dialog box.
Group
Measurement
2-230 DSA/CSA/TDS8X00/B Series Programmer Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA8200 Series and is the answer not in the manual?

Tektronix DSA8200 Series Specifications

General IconGeneral
BrandTektronix
ModelDSA8200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals