Commands Listed in Alphabetical Order
FC3188 selects
clock recovery for the 3.1875 Gb/s bit rate, in accordance with the
proposed 10 Gigabit Fibre Channel (10GFC) standard.
FC4250 select
s a reference-receiver filter for the 4.250 Gb/s bit rate, in accordance
with the ANSI Fibre Channel Physical Interface (FC-PI) Rev 11 draft standard.
FC8500 sele
cts a reference-receiver filter for the 8.5000 Gb/s bit rate, in
accordance with the preliminary 8GFC standard.
FC8500FINA
L
selects a reference-receiver filter for the 8.5000 Gb/s bit rate, in
accordance with the Fibre Channel Optical 8GFC standard.
FC10519 se
lects a reference-receiver filter for the 10.518750 Gb/s bit rate, in
accordance with the proposed 10 Gigabit Fibre Channel (10GFC) standard.
FC11317 s
elects a reference-receiver filter for the 11.317 Gb/s bit r ate, in
accordance with the proposed 10 Gigabit Fibre Channel (10GFC) standard.
FC14025
selects a reference-receiver filter for the 14.02500 Gb/s bit rate, in
accordance with the Fibre Channel Optical 16GFC MM/SM r6.1 standard.
FEC266
6
selects a reference-receiver filter for the 2.6660571 Gb/s bit rate, in
accordance with the ITU-T G.975 Recommendation.
FEC10
664
selects a reference-receiver filter for the 10.66423 Gb/s bit rate, in
accordance with the ITU-T G.975 Recommendation.
FEC1
0709
selects a reference-receiver filter for the 10.709225 Gb/s bit rate, in
accordance with the ITU-T G.709 draft Recommendation.
FEC
12500
selects a reference-receiver filter for the 12.5000 Gb/s bit rate, in
accordance with the Fibre Channel Optical 12.5G FEC standard. Repla ces
the
SFEC12500 argument. If SFEC12500 is set and the filter is queried, the
instrument returns
FEC12500.
FEC43018 selects a reference-r eceiver filter for the 43.018414 Gb/s bit rate, in
accordance with the ITU-T G.709 Draft Recommendation.
FPELECOUT enables the full power electrical output for optical modules. This
is not a filter.
INF2500 selects a reference-receiver filter for the 2.50 Gb/s bit rate, in accordance
with the Infiniband Optical standard. Replaces the
INFINIBAND argument. If
INFINIBAND is set and the filter is queried, the instrument returns INF2500.
INF5000 selects a reference-receiver filter for the 5.0 Gb/s bit rate, in accordance
with the Infiniband Optical standard.
INF14063 selects a reference-receiver filter for the 14.06250 Gb/s bit rate, in
accordance with the Infiniband FDR standard.
INF25781 selects a reference-receiver filter for the 25.781 Gb/s bit rate, in
accordance with the Infiniband EDR standard.