Commands Listed in Alphabetical Order
Examples
EXECute perfor
ms the AutoZero function in the probe.
CH<x>:PRObe:CALibrate (No Query Form)
This command executes a calibration or initialization for the probe attached to
channel 1–4,
if the probe is calibratable. To determine whether the probe is
calibratable, use CH<x>:PRObe:CALibrate:CALIBRATABLe?. The channel is
specified by x, which can range from 1 through 4.
Group
Vertical
Syntax
CH<x>:PRObe:CALibrate {EXECute|INITialize}
Related Commands
CH<x>:PRObe:CALibrate:CALIBRATABLe?
CH<x>:PRObe:CALibrate:STATE?
Arguments
EXECute — executes a calibration for the attached probe.
INITialize — initializes the attached probe.
Examples
CH2:PRObe:CALibrate execute executes a calibration for the attached probe.
0
CH<x>:PRObe:CALibrate:CALIBRATABLe? (Query Only)
This query returns the state of the probe attached to channel 1–4, either 0 ifthe
probe is not calibratable, or 1 if the probe is calibratable. The channel is specified
by x, which can range from 1 through 4.
Group
Vertical
Syntax
CH<x>:PRObe:CALibrate:CALIBRATABLe?
Related Commands
CH<x>:PRObe:CALibrate
CH<x>:PRObe:CALibrate:STATE?
2-226 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual