Commands Listed in Alphabetical Order
(See page 2-76, Tr
igger Command Group.)
(See page 2-61, Search Command Group.)
Returns
<NR1> = 1 if the Ethernet feature is present.
<NR1> = 0 if the Ethernet feature is not present.
CONFIGuration:BUSWAVEFORMS:FLEXRAY? (Query Only)
This query returns a boolean value to indicate whether the optional FlexRay bus
triggering and analysis feature is present.
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or an MDO3FLEX application
module for MDO3000 models.
Group
Configuration
Syntax
CONFIGuration:BUSWAVEFORMS:FLEXRAY?
Related Commands
(See page 2-15, Bus Command Group.)
(See page 2-76, Trigger Command Group.)
(See page 2-61, Search Command Group.)
Returns
<NR1> = 1 if the FlexRay bus feature is present.
<NR1> = 0 if the FlexRay bus feature is not present.
CONFIGuration:BUSWAVEFORMS:I2C? (Query Only)
This query returns a boolean value to indicate whether the optional I
2
C bus
triggering and analysis feature is present.
Conditions
This feature requires installation of a DPO4EMBD application module, or
MDO3EMBD for MDO3000 models.
Group
Configuration
2-246 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual