Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:CAN:DATa:VALue
This command sets the binary data value to be used to search on CAN bus data.
This only applies if the search condition has been set to IDANDDATA or DATA
(using SEARC
H:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application module
on DPO/MSO4000B and MDO4000/B/C models and a MDO3AUTO application
module on MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:DATa:VALue <bin>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:DATa:VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:DAT
a:QUALifier
Arguments
<bin> is the data in binary format.
SEARCH:SEARCH<x>
:TRIGger:A:BUS:B<x>:CAN:FD:BRSBIT
This command specifies the binary data value to be used to search on CAN FD
BRS bits. This only applies if the search condition has been set to FDBRSBIT
(using
SEARCH:SE
ARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDiti on
).
SEARCH:<x> is the search number, which is always 1, and B<x> is the bus
number (1-3), ex
cept for the MDO3000 which only has two buses.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application module
on MDO4000C models and a MDO3AUTO application module on MDO3000
models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:FD:
BRSBIT{ZERo|OFF|0|ONE|ON|1|NOCARE|X|x}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:FD:BRSBIT?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition
2-628 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual