Commands Listed in Alphabetical Order
set to FRAMEtyp
e(usingSEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x> is the bus number
(1-4). 1-3 for the MDO4000C and 1-2 for the MDO3000.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application module
on DPO/MSO4000B and MDO4000/B/C models and a MDO3AUTO application
module on MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:FRAMEtype
{DATA|REMote|ERRor|OVERLoad}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N:FRAMEtype?
Arguments
DATA specifiesadataframe.
REMote specifies a remote frame.
ERRor specifies an error frame.
OVERLoad specifies an overload frame.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN{:IDentifier|:ADDRess}:MODe
This command sets the addressing mode (standard or extended
format) to be used to search on CAN bus data. This only applies if
the search condition has been set to IDANDDATA or DATA (using
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN:CONDition).
SEARCH<x> is the search number, which is always 1, and B<x> is the bus number
(1-4). 1-3 for the MDO4000C and 1-2 for the MDO3000.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application module
on DPO/MSO4000B and MDO4000/B/C models and a MDO3AUTO application
module on MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N{:IDentifier|:
ADDRess}:MODe {STandard|EXTended}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CA N{:IDentifier|:
ADDRess}:MODe?
2-630 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual