Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue
This command specifies the low value to use when searching on the FlexRay bus
frame ID field. (Use SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
FRAMEID:HIV
ALue to set the high value.) The search condition needs to be set
to IDentifier (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:FRAMEID:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:FRAMEID:VALue?
Arguments
<QString> is a quoted string representing the binary data string used for FlexRay
frame ID low value.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:FRAMEID:VALUE
“11001101010”
sets the value of the frame ID is 11001101010.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:FRAMEID:VALUE? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY :FRAMEID:VALUE
"10110010101"
indicating the value of the frame ID is 10110010101.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEType
This command specifies the frame type (normal, payload, null, sync or startup) to
use when searching on FlexRay bus data. The search condition needs to be set to
FRAMEType (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
2-658 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual