Commands Listed in Alphabetical Order
ADDRess specifi
es a search based on an address.
DATA specifies a search based on a data condition.
ADDRANDDATA specifies a search based on an address and data condition.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:I2C:DATa:DIRection
This comman
d specifies the data direction to use for an I2C search: either read,
write, or either.
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4EMBD application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3EMBD application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:I2 C:DATa:DIRection
{READ|WRITE|NOCARE}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:I2 C:DATa:DIRection?
Arguments
READ specifies a read condition.
WRITE specifies a write condition.
NOCARE specifies either a read or write condition.
SEARCH:SEARCH<x>:TR
IGger:A:BUS:B<x>:I2C:DATa:SIZe
This command specifies the length of the data string, in bytes, to be used for an
I2C search, if the search condition is set to
DATA or ADDRAN DDATA (address and
data).
SEARCH<x> is
the search number, which is always 1, and
B<x>
Conditions
This command requires a DPO4EMBD application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3EMBD application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:I2 C:DATa:SIZe <NR1>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:I2 C:DATa:SIZe?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-665