Commands Listed in Alphabetical Order
the search, whe
n the qualifier has been set to
LESSthan, MOREthan, EQ ual,
UNEQual, LESSEQual
or MOREEQual.
SEARCH:SEARC
H1:TRIGger:A:BUS:B1:MIL1553B:STATus:ADD Ress:
VALue " 01000"
sets the lower limit of the range to 01000, if the qualifier has
been set to
INrange or OUTrange.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:STATus:ADDRess:
VALue?
might return “01000”.
SEARCH:SE
ARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:BCR
When the MIL-STD-1553 bus search condition is set to STATus, this command
specifies the status word broadcast command received (BCR) bit value (bit 15)
to be use
dinthesearch.
SEARCH<x> is the search number, which is always 1,
and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:BCR
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:BCR?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
Arguments
0
1
X
sets the value to X (“don’t care”) which is the default.
ZERO s
ets the value to 0.
ONE sets the value to 1.
NOCARE sets the value to X (“don’t care”) which is the default.
OFF sets the value to 0.
ON sets the value to 1.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-685