Commands Listed in Alphabetical Order
Examples
SEARCH:SEARCH
1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:
SUBADdress “01000”
sets the sub-address to be used in the search to 01000.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit
When the MIL-STD-1553 bus search condition is set to COMMAND, this command
specifies that the transmit/receive bit (bit 9) is to be used in the search. The
transmit/receive bit defines the direction of information flow, and is always from
the point of view of the remote terminal.
SEARCH<x> is the search number, which
is always 1, and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:COMMAND:TRBit
{RX|TX|X}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:COMMAND:TRBit?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
SEARCH:SEARCH<
x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
COUNt
Arguments
RX (logic 0) di
rects the instrument to search for a TX or "transmit" from a remote
terminal .
TX (logic 1) directs the instrument to search for an RX or "receive" from a remote
terminal.
X indicates “don’t care".
Examples
TRIGger:A:BUS:B1:MIL1553B:COMMAND:TRBi t TX directs the instrument to
search for a TX or “transmit” from a remote terminal.
TRIGger:A:BUS:B1:MIL1553B:COMMAND:TRBi t TX? might return TX.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
This command specifies a word type or condition within a MIL-STD-1553 bus
word to search for.
SEARCH<x> is the search number, which is always 1, and B<x>
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-677