Commands Listed in Alphabetical Order
Arguments
LESSthan sets t
he Command Address qualifier to less than.
MOREthan sets the Command Address qualifier to greater than.
EQual sets the Command Address qualifier to equal.
UNEQual sets the Command Address qualifier to not equal.
LESSEQual sets the Command Address qualifier to less than or equal.
MOREEQual sets the Command Address qualifier to greater than or equal.
INrange sets the Command Address qualifier to in range.
OUTrange sets the Command Address qualifier to out of range.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:COMMAND:ADDRess:
QUALifier EQual
sets the qualifier to be used with the remote terminal address
to equal.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:COMMAND:ADDRess:
QUALifier?
might return INRANGE.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt
When the MIL-STD-1553 bus search condition is set to COMMAND, this command
specifies the bit pattern for the 5–bit Word Count/Mode Code sub-address field
that is to be used in the search. (Use the commandSEARCH:SEARCH<x>:
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress to specify Word
Count or Mode Code.) In Word Count mode, this field defines the number of data
words that is to be transmitted, or received, depending on the T/R bit setting.
(Use the commandSEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:
COMMAND:TRBit to set the T/R bit.) A word count value of 0 actually indicates
a transfer of 32 data words.
SEARCH<x> is the search number, which is always
1, and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:COMMAND:COUNt
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:COMMAND:COUNt?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
2-674 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual