Commands Listed in Alphabetical Order
SELect:RF_AM
Plitude
This command switches the RF Amplitude vs. Time trace display on or off in the
time domain graticule.
Conditions
MDO4000/B/C models only.
Group
RF
Syntax
SELect:RF_AMPlitude {OFF|ON|0|1}
SELect:RF_AMPlitude?
Arguments
OFF or 0 turns the RF Amplitude vs. Time trace display off.
ON or 1 turns it on.
SELect:RF_AVErage
This command switches the RF Average trace display on or off in the frequency
domain graticule.
Conditions
MDO3000, MDO4000/B, or MDO4000C models with option SA3 or SA6 only.
Group
RF
Syntax
SELect:RF_AVErage {OFF|ON|0|1}
SELect:RF_AVErage?
Arguments
OFF or 0 turns the RF Average trace display off.
ON or 1 turns it on.
SELect:RF_FREQuency
This command switches the RF Frequency vs. Time trace display on or off in the
time domain graticule.
Conditions
MDO4000/B/C models only.
Group
RF