Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:SPI:CONDition
{SS|STARTofframe|MISO|MOSI|MISOMOSI}
TRIGger:A:BU
S:B<x>:SPI:CONDition?
Related Commands
BUS:B<x>:SPI:IDLETime,
BUS:B<x>:SPI:FRAMING
Arguments
SS specifies the Slave Selection condition.
STARTofframe is applicable when BUS:B<x>:SPI:F RAMING is set to
IDLEtime. When the trigger condition is set to STARTofframe,theinstrument
triggers on the first SPI clock after an idle time when there are no clocks.
MISO specifies the Master-In Slave-Out condition.
MOSI specifies the Master-Out Slave-In condition.
MISOMOSI specifies the Master-In Slave-Out and Master-Out Slave-In conditions.
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO}:VALue
This command specifies the binary data string to be used for a SPI trigger if the
trigger condition is MISO or MISOMOSI.
B<x>
Conditions
This command requires a DPO4EMBD application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3EMBD application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO} :VALue <QString>
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO} :VALue?
Arguments
<QString> is the binary data string, where the number of bits is 8 times the
number of bytes specified. The only allowed characters in the string are 0, 1,
and X.
TRIGger:A:BUS:B<x>:SPI:DATa{:OUT|:MOSI}:VALue
This command specifies the binary data string to be used for a SPI trigger if the
trigger condition is MOSI or MISOMOSI.
B<x>
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-857