Commands Listed in Alphabetical Order
Conditions
This command re
quires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:USB:DATa:TYPe {ANY|DATA0|DAT A1}
TRIGger:A:BUS:B<x>:USB:DATa:TYPe?
Related Commands
TRIGger:A:BUS:B<x>:USB:CONDition
Arguments
ANY indicates either a DATA0 or DATA1 data packet type.
DATA0 indicates a DATA0 data packet type.
DATA1 indicates a DATA1 data packet type.
Examples
TRIGGER:A:BUS:B1:USB:DATA:TYPE DATA0 sets the oscilloscope to trigger
on a DATA0 data packet type.
TRIGGER:A:BUS:B1:USB:DATA:TYPE? might return
:TRIGGER:A:BUS:B1:USB:DATA:TYPE DATA1, indicating that the data packet
type is set to DATA1.
TRIGger:A:BUS:B<x>:USB:DATa:VALue
This command specifies the binary data string to be used for the USB trigger when
the trigger condition is DATAPacket.
This command also specifies the binary data string for the lower limit for
inside-of-range and outside-of-range qualifiers for the USB trigger when trigger
condition is DATAPacket.
B<x>
Conditions
This command requires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:USB:DATa:VALue <QString>
TRIGger:A:BUS:B<x>:USB:DATa:VALue?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-863