1.2 Control Panel Keyboard
The main panel keyboard consists
of an LCD Display, LED Indication
and 20 buttons with general
and special functions. A beep is
generated to acknowledge the
pressing of any button. A sound
signal is also used to indicate where
a specific operation is accepted or
rejected.
The user or engineer codes provide
access to the various alarm system
programming and control menus.
The default value of the user menu code is 0000, and the engineer code is
7777.
1.2.1 LED Indication
There are four LEDs on the main panel keyboard which indicate:
220V (green) - lights up permanently to indicate mains power supply and turns off
when disrupted.
TROUBLE (red) - lights up to indicate an open tamper in the system; blinks to indicate
system trouble. When lit it is recommended to contact your installer.
ALARM (red) - lights up permanently to indicate an alarm event; blinks to indicate
entry and exit countdown time for encouraging relative actions for disarming or evacuating
the site.
FIRE (red) - indicates a re in the premises.
1.2.2 Keypad Sounder
Beep - when pressing a button;
Long beep - reject an action;
One long beep followed by a few short ones - conrmation signal;
Short beeps - exit time is running;
Fast beeps - entry time is running out or an important event such as Tamper, Fire, etc.
has occurred;
Double beep every 20 seconds - trouble indication. The double beep signal can be
stopped by holding the