LE910C1 Hardware User Guide
1VV0301298 Rev. 1.08 - 2017-11-14
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA Page
54 of 119
5.3.4. Unconditional Hardware Shutdown
To unconditionally shut down the LE910C1 module, the HW_SHUTDOWN_N pad must be tied low
for at least 200 milliseconds and then released.
A simple circuit for applying unconditional shutdown is shown below:
Figure 8: Circuit for Unconditional Hardware Shutdown
The system power down timing for using HW_SHUTDOWN_N is shown below
Figure 9 Power down timing using HW_SHUTDOWN_N
NOTE:
Recommended values R2 = 47k, R1 = 10kΩ.
NOTE:
Do not use any pull-up resistor on the HW_SHUTDOWN_N line or any totem pole digital
output. Using a pull-up resistor may cause latch-up problems on the LE910C1 power
regulator and improper functioning of the module. The HW_SHUTDOWN_N line must be
connected only in an open-collector configuration.
NOTE:
The Unconditional Hardware Shutdown must always be implemented on the boards, but the
software must use it only as an emergency exit procedure, and not as a normal power-off
operation.
200
mS Sec < T_Hold
VBATT
SHDN_N
SW_RDY
T_RDY ~0 Sec
V_AUX
PWRMON
T_PWRMON ~0 Sec
OFF StateActive State

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C1 Series and is the answer not in the manual?

Telit Wireless Solutions LE910C1 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C1 Series
CategoryControl Unit
LanguageEnglish

Related product manuals