Service and Repair Manual August 2021
Battery Charger
202 GS
â„¢
-30m • 32m • 30 • 32 • 46 • 55 Part No. 1309020GT
Charger status indicators
Remote charger status indicators
1 Error / Fault / USB indicator
2 Charger profile / Error display
3 Error / Fault
Charg er Fault Cod es
Charger Fault Codes
Fault Code
Description
Possible Causes
Solution
F-0-0-1
DC-DC failure: LLC excessive leakage
fault.
Internal charger fault.
Disconnect AC input and battery
pack for 30 seconds.
If fault does not clear, contact
Genie Product Support.
F-0-0-2
PFC failure: PFC excessive leakage
fault.
F-0-0-3 PFC taken too long to boost.
F-0-0-4
Charger unable to calibrate current
offset.
F-0-0-5
Output relay voltage too high when
closed.