Charger Error Codes
Error Code
Description
Condition
Possible Causes
E-0-2-9 CAN Bus error CAN Bus network error. Check CAN Bus connections.
CAN modules not functioning
correctly.
Termination resistance is
~60 ohms.
E-0-3-0 COMM battery module error CAN Bus battery module error. CAN Buss battery module not
functioning correctly.
E-0-3-1 Vref for ADC measurements triggered
alarm
Internal charger error. Disconnect AC input and battery
pack for 30 seconds.
Contact Genie Product Support.
E-0-3-2 CAN Bus heartbeat error CAN Bus heartbeat error. CAN Bus devices not functioning
correctly.
E-0-3-6
Battery temperature sensor charge
profile
Battery temperature sensor is
required by charger profile but is
not installed.
Check battery temperature sensor
connections.
Check charger profile and confirm
battery temperature sensor is
installed.
E-0-3-8 CAN Open Error CAN Open reprogramming failed. Download CAN Open software.
Reprogram charger using USB
Flash Drive.

Table of Contents

Other manuals for Terex GS32MT-101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terex GS32MT-101 and is the answer not in the manual?

Terex GS32MT-101 Specifications

General IconGeneral
BrandTerex
ModelGS32MT-101
CategoryLifting Systems
LanguageEnglish

Related product manuals