Operator's Manual First Edition • Second Printing
Operating Instructions
36 RL4 Vertical Mast Part No. 1266664
Operation of Lights
Note: The engine must be running before the lights
are turned on.
1 Be sure the position of the lights is adjusted
before raising the mast.
2 Start the engine
3 Turn on the main circuit breaker switches on
the control panel.
4 Turn on the lights using the individual light
switches.
Note: Lights can take up to 20 minutes to reach full
intensity.If the lights are turned off and turned back
on again while still warm, they will not light up
again for 20 to 30 minutes.
5 Turn the lights off by turning the circuit breaker
switches to the off position.
6 Make sure the lights are turned off before
engine is shut down.
Electrical Outlets
Electrical outlets are located on the roadside, rear
of the cabinet.
Air Shutoff System (if equipped)
Auto air shutoff system
1 When the auto air shutoff system detects a
fuel-rich environment the engine will shutdown.
2 To reset the system, remove the machine from
the fuel-rich environment.
E-Stop system
1 If needed, push in the fuel cutoff system
Emergency Stop button located on the front of
the machine.
2 Pull out the Emergency Stop button on the
front of the machine to reset the system.
After Each Use
Select a safe parking location—firm level surface,
clear of obstruction and traffic. Retract mast and
stow outriggers before moving machine.
Remove the key or lock cabinet door.