A P P E N D I X
C
CHAPTER 0ASCII C OMMAND /R ESPONSE S TRUCTURE
Cyber Hardened IBUC Console and SSHv2 Command Set
This command set is used with RS232 and SSHv2 interfaces.
Parameters are delimited by “< >” for clarity and are not part of the actual query or
command. Single quotes delimit an exact string used for a parameter.
It is expected that both commands and responses are terminated by using
<LF><CR>, where
<LF> = 0x0A. (Line Feed)
<CR>= 0x0D. (Carriage Return)
Be sure to configure the SSHv2 or RS232 client accordingly.
In some cases users may type queries/commands with structures that differ from what
is expected. In this case one should receive an “Error Response” from the IBUC unit.
In such cases, refer to Table C.1 for a more detailed explanation about such errors.
Table C.1
Error Response Table
Code Error Message Description
1 error = invalid value This is not a valid value for this command.
2 error = bad command This command is not in the command set.
3 error = func not yet done This command has not been implemented.
4 error = bad format in command
One of the parameters is formatted
incorrectly.
5 error = error accessing config storage Unable to access EEPROM.
6 error = ODU fault Cannot switch, target unit has a major fault.
7 error = Please enter valid password Incorrect password has been entered.
8 error = Switch Fault The waveguide switch is faulted.
9 error = ODU Comm Fault Legacy Binary packet checksum is invalid.