EasyManua.ls Logo

Terrasat IBUC 2 - Fuses

Terrasat IBUC 2
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Components | 2-13
Engineered to Endure
Fuses
Table 2.7 lists the fuse markings of the fuses required by different AC-powered IBUC
models. Figure 2.5 on page 2-15 defines the international marking schema.
Table 2.7
Fuse Markings
Signal Power Level
Fuse Markings
115 VAC 230 VAC
C-band
5 W T1.6AL250V T1.6AL250V
10 W T2AL250V T1.6AL250V
15 W T2.5AL250V T1.6AL250V
20 W T3.15AL250V T1.6AL250V
25 W
30 W
T4AL250V T2AL250V
40 W
50 W
T5AL250V T2.5AL250V
60 W T6.3AL250V T3.15AL250V
80 W T10AL250V T5AL250V
100 W
125 W
T12.5AL250V T6.3AL250V
150 W
175 W
200 W
N/A T10AL250V
250 W N/A T12.5AL250V
300 W N/A T15AH500V
400 W N/A T20AH500V
400 W(G) N/A T16AL250V
X-band
5 W T1.6AL250V T1.6AL250V
10 W T2AL250V T1.6AL250V
20 W T3.15AL250V T1.6AL250V
25 W T4AL250V T2AL250V
40 W
50 W
T6.3AL250V T3.15AL250V
60 W T8AL250V T4AL250V
80 W T10AL250V T5AL250V
100 W T12.5AL250V T6.3AL250V
100 W(G) T8AL250V T4AL250V
125 W T12.5AL250V T6.3AL250V
150 W
175 W
N/A T10AL250V
400 W(G) N/A T12.5AL250V

Table of Contents