Cyber Hardened IBUC Console and SSHv2 Command Set | C-13
Engineered to Endure
CLE
Description: Displays or sets the state of the external LED indicator. If disabled, the
external LED indicator will remain off.
Parameters:
<State>
0 - Off / 1 - On
Q
Query: CLE
Response: CLE=<State>
C
Command: CLE=<State>
Response: CLE=<State>