C-34 | Cyber Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R, IBUC G Operations Manual: ASCII Command/Response Structure
Engineered to Endure
TAL
Description: Displays or sets the output low power threshold based upon the Cyber
Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R or IBUC G Rated Power Level
(RPL). See Table C.4 on page C-37. This setting must be less than the TAH setting.
Parameters:
<Value>
Output low power threshold [RPL – 20 dB to RPL + 1 dB]
TAS
Description: Displays or sets the Tx simulated alarm setting.
Parameter:
<Setting>
0 = no alarm, 1 = alarm
Q
Query: TAL
Response: TAL=<Value>
C
Command: TAL=<Value>
Response: TAL=<Value>
Q
Query: TAS
Response: TAS=<Setting>
C
Command: TAS=<Setting>
Response: TAS=<Setting>