C-42 | Cyber Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R, IBUC G Operations Manual: ASCII Command/Response Structure
TPM
Description: Displays or configures the power monitoring mode of the Cyber
Hardened IBUC 2, IBUC 2e, IBUC 2G, IBUC R or IBUC G. When configured for
burst, TBT must also be set. Default values for the TBT command are given in
Table C.4 on page C-37. If CW is selected power is read continuously. If burst is
selected the power reading only changes when a valid burst is detected.
Parameter:
<Value>
0 = CW / 1 = Burst
TPO
Description: Displays the current output power of the Cyber Hardened IBUC 2,
IBUC 2e, IBUC 2G, IBUC R or IBUC G. If TPM is set to burst, this will be the last
valid burst sample of the output power. Use the TFR command to configure the
desired frequency to be monitored. This is a read-only command.
Parameter:
<xx.xx>
Current output power [decimal number]
Query: TPM
Response: TPM=<Value>
Command: TPM=<Value>
Response: TPM=<Value>
Query: TPO
Response: Tx Output Power=<xx.xx> dBm