EasyManua.ls Logo

TESTO 770 - Page 32

TESTO 770
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Technical data
32
Feature
Measuring
range
19
Resolution
Accuracy
Apparent power
600.0 VA
6.000 kVA
60.00 kVA
600.0 kVA
0.1 VA
0.001 kVA
0.01 kVA
0.1 kVA
± (15 % of m.v. + 15 digits)
for I = 1 A to 10 A, V > 10 V
± (2.0 % of m.v. + 5 digits)
for I > 10 A, V > 10 V
14
Power for
DC/voltage
600.0 W
6.000 kW
60.00 kW
600.0 kW
0.1 W
0.001 kW
0.01 kW
0.1 kW
± (15 % of m.v. + 15 digits)
for I = 1 A to 10 A, V > 10 V
± (2.0 % of m.v. + 5 digits)
for I > 10 A, V > 10 V
24
Power factor
-1.00 to +1.00
0.01
± (5 % of m.v. + 5 digits)
for I > 10 A, V > 10 V
24
Capacitance
measurement
6.000 nF
25
0.001 nF
± (10 % of m.v. + 25 digits)
60.00 nF
0.01 nF
± (2 % of m.v. + 25 digits)
600.0 nF
0.1 nF
± (1.5 % of m.v. + 5 digits)
6.000 µF
0.001 µF
± (1.5 % of m.v. + 5 digits)
60.00 µF
0.01 µF
± (1.5 % of m.v. + 5 digits)
600.0 µF
0.1 µF
± (2 % of m.v. + 10 digits)
6.000 mF
1 µF
± 10 % of m.v.
60.00 mF
26
10 µF
± 10 % of m.v.
Frequency with
voltage
27
99.99 Hz
999.9 Hz
9.999 kHz
0.01 Hz
0.1 Hz
0.001 kHz
± (0.08 % of m.v. + 3 digits)
Frequency with
current
17
99.99 Hz
999.9 Hz
9.999 kHz
0.01 Hz
0.1 Hz
0.001 kHz
± (0.08 % of m.v. + 3 digits)
for I > 2 A
± (0.1 % of m.v. + 15 digits)
for 0.6 A < I < 2 A
28
25
Accuracy valid for capacitance values >2 nF
26
Maximum measurement duraon is 12.2 s
27
Frequency measurement is not specied for alternang currents or voltages below 1 % of the
smallest respecve measuring range
28
40~1kHz

Table of Contents

Related product manuals