Contains FCC ID: N8NLSD4WF0459
T1, T2, T3, H2:
FCC ID: WAF-0572203X
H1:
FCC ID: WAF-05722034
FCC Warnings
Feature Values
WLAN Range 100 m
WLAN type LSD4WF0459-01D0
WLAN radio class Accord with the standard of IEEE
802.11b/g/n
Company Lierda Technology Group co., LTD
RF Band 2412-2472MHz
Transmitter Power 13.42dBm
Acc. to EN 12830 -S,T,A,C,D,1,
-25…+25°C
IC Warnings
This instrument complies with Part 15C of the FCC Rules and
Industry Canada RSS-210 (revision 8). Commissioning is subject to
the following two conditions:
(1) This instrument must not cause any harmful interference and
(2) this instrument must be able to cope with interference, even if
this has undesirable effects on operation.
Cet appareil satisfait à la partie 15C des directives FCC et au standard Industrie Canada
RSS-210 (révision 8). Sa mise en service est soumise aux deux conditions suivantes :
(1) cet appareil ne doit causer aucune interférence dangereuse et
(2) cet appareil doit supporter toute interférence, y compris des interférences qui
provoquerait des opérations indésirables.
FCC Warnings
Information from the FCC (Federal Communications Commission)
For your own safety
Shielded cables should be used for a composite interface. This is to ensure continued
protection against radio frequency interference.
FCC warning statement
This equipment has been tested and found to comply with the limits for a Class C digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a

Other manuals for TESTO Saveris 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO Saveris 2 and is the answer not in the manual?

TESTO Saveris 2 Specifications

General IconGeneral
Protection ClassIP54
Measurement ParametersTemperature, humidity, pressure
ConnectivityWiFi
Data StorageInternal memory
Power SupplyReplaceable batteries
Operating Temperature-30 to +50 °C
Battery Life24 months
Humidity Range0 to 100% RH
Alarmsemail/SMS notification
SoftwareTesto Cloud software
CertificationsEN 12830