ERROR:
NONE
RCV
BUFFER:
2K
ROM: XU310;0;GOTHIC;07;B;140C
XU303;ACS
1;
1 0;0000
XU304;ACS2; 10;2F66
XU302;ACS3;10;2317
XU105;PCS1;08;A764
RS232:
DSR(6)-ON; CTS(5)-ON; DCD(8)-ON
NOTE
The
IRS232"
line
of
the status report
appears only
if
a serial printer/host
interface
has
been
selected in the con-
figuration mode (code
13, 14,
or
15
ON).
The example above reports:
The printer reported no error code (NONE).
4-2
2K
of
RAM
is
configured for receive buffer
use.
A Gothic character-set
ROM
(revision
level 07; identifier B used
for
character set
selection with escape sequences; check-
sum value hexadecimal
140C)
is installed
on the Applications Controller (AC) board
in socket XU310 (which is logical position
o for escape sequence use).
NOTE
The identifier is called z and the logical
position
(0
-
4)
is called N
in
the charac-
ter set designation
escape
sequences
(see
Section
5).
System ROMs
are
in
locations XU302,
XU303,
and
XU304
on
the Applications
Controller (AC) board and
in
location
XU105 on the Printer Controller
(PC)
board.
Lines
6,
5,
and 8
of
the 25-line RS-232
connector
are
ON.
NOTE
Lines
6,
5,
and 8
of
the 25-line
RS-232
connector
are
biased
on
when no
connection to the host exists. When the
host connection
is
made these
lines
will
indicate the conditions dictated by the
host.
4.1.2 Error Codes
Table
4-1
summarizes error codes and corrective
actions.
If
you
need
to
call
a service representative,
any error codes that appear
in
the status report pro-
vide useful information for diagnosing printer prob-
lems.