0.5
CHANGING
SIGNAL
GROUND
/
PROTECTION
GROUND
WARNING
Disconnect
the
power
cable
before
removing
the
cover!
Failure
to
remove
the
power
cable
will
result
in
a
serious
shock
hazard.
Chang-
ing
the
signal
ground/protection
ground
jumper
should
only
be
done
by
a
qualified
technical
person.
The Model 880 Printer
is
normally assembled
with
protection ground and signal ground connected
by a jumper
plug between
E4
and
E5
on the
Moth-
erboard.
When a system needs the
signal-chassis ground
to
be
isolated, remove the jumper plug between
E4
and
E5
and place
it
between
E4
and
E3
for
storage.
If
you are
not
sure which configuration
to
use,
measure the resistance between pins
1 and 7
of
00
@
D
E3
E4
.
E5
.
the serial data cable
with
the cable connected
to
the system.
If
an
open circuit
is
measured, the
jumper
plug must
be
installed between
E4
and
E5.
If
a short circuit
is
measured, the jumper plug
between
E4
and
E5
must be removed and installed
between
E4
and
E3
for
storage. Refer
to
Figures
0-2and
0-3.
OVERHEAD VIEW
GROUND JUMPER
PLUG LOCATION
SCREWS
SCREWS
-
.r--
---,1
2222627-38
Figure
0-2.
Locations
of
Printer
Cover
Screws
2222627-39
Figure
0-3.
Signal
Ground/Protection
Ground
Jumper
Plug
0-3