EasyManua.ls Logo

Texecom Premier 24 - Event Log Descriptions; Log Event

Texecom Premier 24
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier Series Master User Guide Programming the Alarm System
INS177 31
Event Log Descriptions
Log Event Description
KSW ### Active A Keyswitch zone type has been activated (zone number ###)
RKP #,# MEDICAL A Medical alarm (7 & 9) has occurred from keypad number #,#
RKP #,# FIRE A Fire alarm (4 & 6) has occurred from keypad number #,#
RKP AUD PA #,# An Audible PA alarm (1 & 3) has occurred from keypad number #,#
RKP SIL PA #,# A Silent PA alarm (1 & 3) has occurred from keypad number #,#
DURESS User ## has entered a Duress Code at a keypad
ALARM Active An Intruder alarm signal has been activated for area ?
BELL Active The Bell output has been activated for area ?
REARM LOCK ### Zone ### has re-armed after causing an alarm
CROSS ### A Verified Cross Zone Alarm has occurred from zone ###
USER ## User ## has entered their code
AREAS EXIT The Exit mode has been started for area ?
ARMING FAILED A Exit Error-Arm Fail has occurred on area ?
AREAS ENTRY The Entry mode has been started for area ?
ARMING SUITE Area Arm Suite # was used to arm the system
ARMED WITH L/F The system has been armed with a Line Fault condition present
AREA Armed Area ? has been armed
AREA Disarmed Area ? has been disarmed
PART Armed Area ? has been Part Armed
TIME Armed Area ? was armed automatically using one of the timer controls
TIME Disarmed Area ? was disarmed automatically using one of the timer controls
DEFERRED The arming mode was deferred for area ?
ALARM ABORT An Open After Alarm-Abort has occurred for area ?
REMOTE Armed Area ? was armed using the Wintex UDL software
REMOTE Disarmed Area ? was disarmed using the Wintex UDL software
QUICK Armed Quick Arm from keypad #,#
RECENT Armed Area ? has been armed recently
#,# RESET AREAS Area have been reset using keypad #,# following an Intruder alarm
Engineer Reset A reset has been performed using an Engineers code
Anti-Code Reset A reset has been performed using the Anti-code reset procedure
Remote Reset A reset has been performed using the ‘Remote Reset’ input
Redcare Reset A reset has been performed by the Redcare
Key switch Reset A reset has been performed using a key switch
User Reset A reset has been performed using a User code
EXP #,# Reset A reset has been performed using the input on expander #,#