Programming the Alarm System Premier Series Master User Guide
36 INS177
Walk Testing the System
Users with access to this option can walk test any of the zones on the system to ensure that
they operate correctly. A walk test can only be performed when the system or area is disarmed.
24 Hour zones (except Fire and Tampers) are disabled during walk test allowing Audible PA
buttons, Silent PA buttons, etc. to be tested.
To perform a walk test, proceed as follows:
Enter a valid User code
1111
K($6(=$9"13$3(
%&'$+653,'E
2
Press
+
K($6(=$9"13
P5,&$7,1=E
Press
#
K($6(=$9"13$3(
Q.,9$0-,13$C(2E
Press
4
K($6(=$9"13$3(
K($M"#N$3,53E
Press
#
M"#N$3,53$"&,"5L
$$L$IIIIII))$[
Use keys
!
-
5
to select an area for walk testing
M"#N$3,53$"&,"5L
$$L$%IIIII))$[
Press
#
to start the walk test
$$$$I$Z:Z0$I
Every time zones are activated the keypad will chime
O(1,$>A>L%/3.-,
C(=12,$K,3,/3(&$L
Press
+
, when finished
Press
)
to exit the menu
The display will return to normal.