Fault Messages
7".15$8(9,&$:;;
$<=,$>?$7"&$@>>A
There is a Mains failure (the keypad may chime every minute, enter a valid
User code or press
)
to stop the chime). The display will automatically
clear when mains is reapplied.
8B(1,$C.1,$*"=#3
$<=,$>?$7"&$@>>A
There is a Phone Line fault (the keypad may chime every minute, enter a
valid User code or press
)
to stop the chime). The display will
automatically clear when line fault clears.
D"33,&6$*"=#3
$<=,$>?$7"&$@>>A
There is a fault with the standby battery (the keypad may chime every
minute, enter a valid User code or press
)
to stop the chime). Contact
your alarm company immediately.
EEEEEEEE$<"'F,&
$<=,$>?$7"&$@>>A
There is a Tamper fault (the alarm will sound, enter a valid User code to
silence the alarm, this fault cannot normally be cleared). Contact your alarm
company immediately.
+,&-./,$4,G=.&,H
$<=,$>?$7"&$@>>A
The service timer has expired indicating that the system requires a service
or a fault has occurred that requires attention (the system can normally still
be used). Contact your alarm company to advise.
I$%&,"$+,/=&,H$I
$<=,$>?$7"&$@>>A
The keypad has been disabled to prevent unauthorised access. This
normally occurs when a zone programmed as ‘Security Key’ is active, the
display will automatically clear when the zone returns to normal.
$%/3.-.36$*"=#3
$<=,$>?$7"&$@>>A
A zone with the ‘Activity’ attribute has not been activated within the activity time
period, this may be caused by an obstruction (view the zone status to find out
which zone has not activated then activate the zone to clear the fault).
EEEE$*=5,$D#(91
$<=,$>?$7"&$@>>A
A fuse has blown (the alarm will sound, enter a valid User code to silence the
alarm, this fault cannot be cleared). Contact your alarm company immediately.
%&,"$*".#,H$<,53
$<=,$>?$7"&$@>>A
Zones that have been placed on test by the engineer have failed the test
(the system can still be used). Contact your alarm company to advise.
4,'(3,$J,6F"H$.5
1(9$C:!J0K$(=3
Too many invalid code attempts have caused the keypad to lock out. The
keypad will normally remain like this for 5 minutes.
<.',$%&'.12$L
$$$$%)))))))
Areas are being armed using one of the control timers (enter a valid User
code to defer the arming).
%#"&'$012.1,,&
M(&N.12$:1$+.3,
The alarm engineer has logged into the programming menu and is working on
site (this message will clear when the engineer logs off or the system is armed).
!"
When alarm information is being displayed, pressing the SCROLL key will slow
down the display and also allow manual scrolling through the events.