Premier Elite Ricochet Kits Quick Guide
INS626 13
Area Programming
05: Remote Disarm 25: Log Part Omits
06: Panel Tamper 26: Multi Knock Area
07: Bell Tamper 27: UDL Keypad
08: Auxiliary Tamper 28: Auto Chime (C2A)
09: Panel Speaker 29: Confirm in Entry
10: Bell & Strobe op 30: Conf. After Entry
11: Alarm Eng Reset 31: Enable Part Arms
12: Confirmation Reset 32: Bell Squawk
13: Tamper Eng Reset 33: Fob After Entry
14: Anti-code Reset 34: Armed = Coms
15: Phone Line Fault 35: 2-Wire Smoke
16: Arm With L/Fault 36: Fault Eng Reset
17: AC Mains Fail 37: L/Fault Eng Rst
18: Arm With AC Fail 38: AC Fail Eng Rst
19: Area Arm Coms 39 Anti-Masking When Armed
20: Part Arm Coms
Time Arm Areas
Use to select an area, to toggle between the arm and disarm timer, - to select timers, to
Area Text
Use
to select an area, to edit, - to select characters (press the required key the appropriate
number of times),
to accept
Global Options
System Timers
Use
to select a timer, - to enter a value, to accept
00: Exit Settle Time 12: Pulse Period 2 24: Zone Response
01: Global Bell Dly. 13: Pulse Period 3 25: Keypad PA Delay
02: Global Bell Dur. 14: Line Fault Delay 26: Confirmation Dly
03: Double Knock Dly 15: AC Off Delay 27: Warning Delay
04: Beam Pair Time 16: Batt Test Period 28: Keypad Lock Time
05: Activity Delay 17: Batt Test Time 29: Eng. Log Off Dly
06: Abort Delay 18: Soak Test Time 30: Fire Bell Delay
07: Courtesy Time 19: Service Interval 31: Forced Entry Dly
08: Defer Arming By 20: Test Call Every 32: Supervision Time
09: Auto Arm Delay 21: Min Random Time 33: Poll IP Every
10: Menu Time Out 22: Max Random Time
11: Pulse Period 1 23: Door Strike Time
System Config.
Use to select an option, to change the option, to accept
00: (No Bell/Bell on) Arm Fail 19: (Auto/Manual) Area Select 38: (Enable/Disable) RF FOB PA
01: Bell is an (SAB/SCB) 20: (Predictive/Normal) Text 39: Mask=(Fault/Alarm)
02: Clock is (12Hr/24Hr) 21: Zone Short=(Active/Tamper) 40: FOB PA (Audible/Silent)
03: (Manual/Auto) BST/GMT 22: R/R=(Reset Only/Silence/RST) 41: PSU Batt (Monitor/No Flts)
04: (Hide/View) Armed Areas 23: User Codes (Pulse/Latch) 42: Exp Loss Tamp (On/Off)
05: (Area/Global) Bell Time 24: Test Call = (Timed/Timed) 43: Soak Test Warn (On/Off)
06: 24Hr Omit (Global/Local) 25: Batt Test = (Timed/Disarm) 44: Fob Batt Warn (On/Off)
07: (Leave/Remove) Omits 26: Bell = (1
st
Alarm/2
nd
Alarm) 45: Entry Stray (On/Off)
08: Away (Override/Enforce)
Dl
27: SNDR = (1
st
Alarm/2
nd
Alarm) 46: BS Entry Stray (On/Off)
09: NVM is (Unlocked/Locked) 28: Conf. = (Instant/Delayed) 47: Tamper = Confirmed (No
Confirm/Confirm)
10: Engineer (Only/+ User) 29: Abort = (Eng. Reset/User
Reset)
48: Radio 2 Step Arm (2 Steps/1
Step)
11: Chime (Audible/Visible) 30: (Auto/Manual) AV Outputs 49: Radio Step1 (Zone/RKP)
12: Omit Tampers (NO/YES) 31: Clock = (50Hz/Crystal) 50: Radio Step 2 (Fob/Zone)
13: (Offline/Online) Printing 32: (40/80) Column Printer 51: Conf Hold Up (Enabled/None)
14: Activity Fault (View/Hide) 33: (Enable/Disable) Text 52: Max Log msgs (3/Off)
15: (Hide/View) Exit Errors 34: EN50131 (Disabled/Enabled) 53: Code entry timed (On/Off)
16: (No/Enable) Code Tampers 35: (2
nd
Zone /1
st
Zone) = Confirm 54: PD6662:2010 (On/Off)
17: Code Tamp (Alarms/Locks) 36: (Global/Local) Keypads
18: Areas (1-8/A-H) & I-P 37: Panel Grade (2/3)
System Options
Use to select an Option, - to enter a value, to accept
0: Advisory Volume 4: Multiple Knocks 8: Language