INS884EN-4 22/87
Port Protocol Direction
Destination Host
Address
Destination IP
Address
Note
123 UDP Outbound
server0.pool.ntp.org
server1.pool.ntp.org
server2.pool.ntp.org
server3.pool.ntp.org
IP address may
change from
region to region
because it is a
pooling server
system and
very dynamic.
Used for
clock sync
8883 TCP
Outbound
broker.texe.com
34.249.140.153
52.209.59.219
34.248.181.184
Only one
connection
is made
depending
on which
broker the
panel
account is
registered
to. This
can be
seen from
Texecom
Cloud
service on
the "panel
overview"
page.
broker2.texe.com 63.35.94.43
broker3.texe.com 52.31.23.9
broker4.texe.com 63.35.94.43
broker5.texe.com 52.211.84.220
broker6.texe.com 54.216.76.216
broker7.texe.com 54.76.107.134
broker8.texe.com 52.16.123.2
broker8.texe.com 34.248.136.241
443 TCP Outbound https://cloud.texe.com
34.248.181.184
52.209.59.219
34.249.140.153
Question and Answer IconNeed help?

Do you have a question about the Texecom SmartCom 4G and is the answer not in the manual?

Texecom SmartCom 4G Specifications

General IconGeneral
Power Supply12V DC
Remote Arm/DisarmYes
Push NotificationsYes
Operating Temperature-10°C to +55°C
Network Type4G
CompatibilityPremier Elite Systems
Communication Technology4G LTE
Mobile App SupportYes
IP ConnectivityYes