Veritas R8 Plus & Excel Installation Manual Programming the Control Panel
INS045-14 33
Null
The Null level is the only level which can be changed both by a
Master User and by a Boss Engineer. The Null level has two
functions:
If a user is no longer required, their Access Level should be
changed to Null. This will erase the associated Access
code.
To change a Customer Access Type to an Installer Access
Type, or vice versa, it must first be changed to the Null
Code Type.
Boss Engineer
Boss Engineer level can access all the Engineer programming
options and can also assign Access Level Engineer (Level 2).
Access Types
There are two Access Types, Customer and Installer. The Boss
Engineer Level can only program the Installer Types. The Master
User Level can only program the Customer Types.
The table below shows a summary of each Access Level and who
is responsible for assigning the Level:
Access
Level
Access
Level
Number
Access
Type
Can be
Programmed by
User

Customer Master

Engineer

Installer Boss

PA (Panic)

Customer Master

Duress

Customer Master

Master User

Customer Master

Cleaner

Customer Master

Null

Customer
Installer
Master

Boss

Boss
Engineer

Installer
Boss

The Master User can only assign Customer Access Types
and the Boss Engineer can only assign Installer Access
Types.
Changing Your Own Access Code

Each user has a programmable 4 digit Personal Identification
Number (PIN) which the user enters in order to operate the alarm
system.
Every user has the ability to change their own 4 digit Access code,
as follows:
From the Programming Menu, enter

. The display will look
like this.
12 3 456 7 8
Uns et
Ta mpe r
Zones


Enter the new Access code

. The display will
indicate as each digit of the new code is entered. Press
,
the system will chime to confirm the new code has been accepted.
The system will then automatically revert to the Programming
Menu.
Assigning New Access Codes

-

The Master User can assign a new Access code or change an
existing Access code providing it is a Customer Type. The Boss
Engineer can assign a new Access code or change an existing
Access code providing it is an Installer Type.
Programming Access Codes

-

From the Programming Menu, enter
followed by the User
Number
to
i.e. for User 5, enter

. The display will
look like this.
12 3 456 7 8
Uns et
Ta mpe r
Zones


Enter the new Access code

. The display will
indicate as each digit of the new code is entered. Press
,
the system will chime to confirm the new code has been accepted.
The system will then automatically revert to the Programming
Menu.
Programming Access Levels

-

From the Programming Menu, enter
followed by the User
Number
to
i.e. for User 5, enter

. The display will
show the Access Level currently selected.
12 3 456 7 8
Uns et
Ta mpe r
Zones


Press the number of the Access Level required
, i.e. for
User, enter 1. Press
, the system will chime to confirm
the new Access Level has been accepted. The system will then
automatically revert to the Programming Menu.