Quick Reference and Factory Settings Veritas R8 Plus & Excel Installation Manual
6 INS045-14
Miscellaneous Options
Option Miscellaneous Selections Zero

Factory Setting
1 Cancel Strobe with Bell Off
2 Keypad PA (pressing
and
together causes PA alarm) Off
3 Single Button Setting On
4 Silent Part Set Confirmation Tone Off
5 EN 50131-1 Requirements Off
6 Time Limit Engineer Access Off
7 Reset Button Cancels Setting On
8 Automatically Omit a Mains Fail Condition (Auto-Omit AC Off) Off
Option Miscellaneous Selections One

Factory Setting
1 Internal Sounders Only on Unset Tamper Alarm On
2 Internal Sounders Only on Part Set Zone Alarm On
3 Internal Sounders Only on Part Set Tamper Alarm On
4 Silent Part Set (no exit tone on part set) Off
5 High Level Chime (chime at full volume) Off
6 Invert Bell Output (negative removed instead of negative applied, useful for SCBs) Off
7 Final Door Set (system sets 3 seconds after final door closure) Off
8 Unlock Engineer Code (re-loading factory settings restores default Engineer code) On
Option Miscellaneous Selections Two

Factory Setting
1 Engineer Reset on Any Alarm (see page 21) Off
2 Engineer Reset on Tamper Alarm (see page 21) Off
3 Disable User Ability to Omit Tamper Off
4 Code PIN Tamper (tamper alarm after 16 invalid key presses when unset) Off
5 Random Number Remote Reset (RNRR, see page 21) Off
6 Push To Set (see page 22) Off
7 Strobe Flash on Full Set (see page 21) On
8 Invert Switched Positive Output (off = negative removed, on = negative applied) Off
Option Miscellaneous Selections Three

Factory Setting
1 Mains Frequency (off = 50Hz, on = 60Hz) Off
2 EOL Tamper Alarm on Zone Short Circuit (S/C) Off
3 EOL Tamper Alarm on Zone Open Circuit (O/C) Off
4 Enable DD 243:2002 Options (see page 22) Off
5 Enable Confirmation Signal After Entry Time Out Off
6
Operation of a Keyswitch Zone is Momentary (Momentary KEYSW)
Off
7 Automatically Omit Zone on Alarm Off
8 Automatically Omit Keyswitch Zone when EOL Tampered Off
Option Communicator Selections

Factory Setting
1 Communicator Outputs Latch until System is Reset On
2 Line Monitor Input causes Tamper Alarm on Line Cut Off
3 Invert Communicator Outputs (off = active low, on = active high) Off
4 Invert Remote Reset Input (off = active if negative removed, on = active if negative applied) Off
5 Remote Reset Input Silences Internal Sounder during Alarm Off
6 Remote Reset Input Clears Engineer Reset (see page 21) Off
7 Silent PA Off
8 Enable 90 Second Abort Time Limit On

Table of Contents

Other manuals for Texecom Veritas R8 Plus