EasyManuals Logo

Thecus N2200 User Manual

Thecus N2200
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
a special file storage layout in the storage volume. A larger stripe
size is better for large files.
Data Percentage The percentage of the RAID volume that will be used to store data.
Create Press this button to configure a file system and create the RAID
storage volume.
To create a RAID volume, follow the steps below:
1. On the RAID Information screen, click create.
2. On the RAID Configuration screen, set the RAID storage space as JBOD,
RAID 0, RAID 1— see Appendix C: RAID Basics for a detailed description
of each.
3. Specify a RAID ID.
4. Specify a stripe size — 64K is the default setting.
5. Specify the percentage allocated for user data by drag the horizontal bar.
6. Press Create to build the RAID storage volume.
Building a RAID volume
and RAID mode. In gene
“RAID Building” then th
may take time, depending on the size of hard drives
ral, while the RAID volume building process is up to
e data volume is capable to be accessed.
NOTE
Creating RAID destroys a
unrecoverable.
ll data in the current RAID volume. The data is
WARNING
RAID Level
You can set the storage volume as JBOD, RAID 0, RAID 1. RAID configuration is
usually required only when you first set up the device. A brief description of each
RAID setting follows:
RAID Levels
Level Description
JBOD The storage volume is a single HDD with no RAID support. JBOD
requires a minimum of 1 disk.
RAID 0 Provides data striping but no redundancy. Improves performance
but not data safety. RAID 0 requires a minimum of 2 disks.
RAID 1 Offers disk mirroring. Provides twice the read rate of single disks,
but same write rate. RAID 1 requires a minimum of 2 disks.
If the administrator improperly removes a hard disk that should not be
removed when RAID status is degraded, all data will be lost.
WARNING
45

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N2200 and is the answer not in the manual?

Thecus N2200 Specifications

General IconGeneral
RAID levels0, 1, JBOD
Storage drive size2.5/3.5 \
Storage drive capacity2000 GB
Storage drive interfaceSerial ATA, Serial ATA II
Storage drives installedYes
Installed storage drive typeHDD
Total installed storage capacity4 TB
Number of storage drives installed2
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 7/2000/XP/2003/Vista UNIX/Linux Mac OS 9/X
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports1
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity0
Processor model-
Ethernet LAN data rates10, 100, 1000 Mbit/s
Product colorBlack
TypeNAS
Device classHome & Home Office

Related product manuals