Page #43 background imageLoading...
Page #43 background image
shows total count of hours (or minutes, or seconds, depending on
manufacturer) in power-on state.
Temperature Celsius The current temperature of the hard disk in degrees Celsius
Reallocated Sector
Count
Count of reallocated sectors. When the hard drive finds a
read/write/verification error, it marks this sector as "reallocated"
and transfers data to a special reserved area (spare area).
This process is also known as remapping and "reallocated" sectors
are called remaps. This is why, on a modern hard disks, you can
not see "bad blocks" while testing the surface - all bad blocks are
hidden in reallocated sectors. However, the more sectors that are
reallocated, the more a decrease (up to 10% or more) can be
noticed in disk read/write speeds.
Current Pending Sector
Current count of unstable sectors (waiting for remapping). The
raw value of this attribute indicates the total number of sectors
waiting for remapping. Later, when some of these sectors are read
successfully, the value is decreased. If errors still occur when
reading sectors, the hard drive will try to restore the data, transfer
it to the reserved disk area (spare area), and mark this sector as
remapped. If this attribute value remains at zero, it indicates that
the quality of the corresponding surface area is low.
Test Type
Set short or long time to test.
Test Result
Result of the test.
Test Time
Total time of the test.
NOTE
If the Reallocated Secto
disk drive > 0 , the stat
used to alert the system
and they should replac
r Count > 32 or Current Pending Sector of a hard
us of the disk will show “Warning”. This warning is only
administrator that there are bad sectors on the disk,
e those disks as soon as possible.
Bad Block Scan
On the Disks Information screen, you may also perform a disk bad block scan.
Simply click Yet to start to begin scanning. The result is only for reference and
system will not take any action from its result.
The testing result will be stay until the next system reboot with “Yet to start
displayed as default.
RAID Information
From the Storage menu, choose the RAID item and the RAID Information screen
appears.
This screen lists the RAID volumes currently residing on the N2200. From this
screen, you can get information about the status of your RAID volumes, as well as
43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N2200 and is the answer not in the manual?

Thecus N2200 Specifications

General IconGeneral
RAID levels0, 1, JBOD
Storage drive size2.5/3.5 \
Storage drive capacity2000 GB
Storage drive interfaceSerial ATA, Serial ATA II
Storage drives installedYes
Installed storage drive typeHDD
Total installed storage capacity4 TB
Number of storage drives installed2
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 7/2000/XP/2003/Vista UNIX/Linux Mac OS 9/X
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports1
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity0
Processor model-
Ethernet LAN data rates10, 100, 1000 Mbit/s
Product colorBlack
TypeNAS
Device classHome & Home Office

Related product manuals