Unit Description
25
Defrost Operation
The Defrost mode can be initiated any time the
evaporator coil temperature is below 42.0 F
(5.6 C). Defrost is initiated automatically by the
defrost air switch and defrost timer or manually
by pressing the Manual Defrost switch.
When a Defrost cycle is initiated, the defrost relay
energizes the damper solenoid and pilot solenoid.
The unit remains on Defrost until the evaporator
coil temperature rises to 52.0 F (11.1 C), causing
the defrost termination switch to open. When the
defrost termination switch opens, the unit may
shift back to the Cool or Heat mode, or the Null
mode (optional Start/Stop operation).
If the thermostat calls for the Null mode (optional
Start/Stop operation) while the unit is defrosting,
the unit will continue to run until defrosting is
complete. Then the unit will stop.
Serial Number Locations
Unit: Nameplate on top of roadside of the unit
frame above the switch panel.
Engine: Nameplate on top of the rocker arm cover.
Compressor: Stamped on the side below the sight
glass.
Electric Motor: Nameplate attached to the motor
housing.
Unit Features
TK 3.95 Diesel Engine
X426 Compressor
ThermoGUARD V Microprocessor Controller
Tapered Roller Bearing Fanshaft & Idler
Heavy Duty Oil Bath Air Cleaner
Three-way Valve Refrigeration System
One-piece Main Wiring Harness
Spin-on Fuel Filter
Spin-on Full Flow Oil Filter
Electric Fuel Pump
Coolant Expansion Tank with Coolant
Indicator
23 Ampere Alternator
Defrost Timer (Part of TG-V)
Air Defrost Switch
Electronic Engine Hourmeter
Alternator Discharge Light
Digital Thermometer (Part of TG-V)
TherMax Defrost/Heating System
R-404A.
Unit Options
Electric Standby Motor (Model 50)
CYCLE-SENTRY Start/Stop Controls
Remote Control Box (outside, beneath unit)
In-Cab w/TG-V
Hourmeter, Electric Operation (Model 50)
Dry-type Air Cleaner
Fuel Heater
Ammeter
Silicone Coolant Hoses
Oil Pressure Gauge
Remote Indicator Lights
Top Screen
Engine Coolant Temperature Gauge
Suction Pressure Gauge
Electric Heaters
Spin-on Bypass Oil Filter
R-134a.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King RD-II MAX and is the answer not in the manual?

Thermo King RD-II MAX Specifications

General IconGeneral
BrandThermo King
ModelRD-II MAX
CategoryRefrigerator
LanguageEnglish

Related product manuals