Specifications (Rev. 04/03)
3
ELECTRICAL COMPONENTS
Current Draw (Amps) Resistance—
at 12.5 Vdc (Ohms)
Glow Plug 8.3 1.5 ± .15
Fuel Solenoid: Pull In
Hold In
30 to 40 .41 to.31
.97 12.8
Pilot Solenoid .657 19
Starter Motor 90 to 105 (cranking)
Damper Solenoid 5.7 2.2
DC Circuit Breakers 50 amp
20 amp
High Speed Solenoid 5 amp (approx) 2.5 (approx.)
Electrical Standby (Model 50 Unit Only)
Electric Motor:
Voltage/Phase/Frequency Horsepower Kilowatts rpm
Full Load
(amps)
Locked
Rotor
Amps
230/3/60 7.5 5.6 1765 21.2 70.1
460/3/60 7.5 5.6 1765 10.6 35.0
200/3/50 6.25 4.7 1465 21.4 65.5
380/3/50 6.25 4.7 1465 10.7 32.8
Electric Heater Strips (Optional): Number
Watts (each)
3
750
Resistance (each cold and disconnected) 67.5 ohms
STANDBY POWER REQUIREMENTS
Supply Circuit Breaker 30 amp/230 V
20 amp/460 V
Extension Cord Size Up to 50 ft—12 gauge
75 ft—10 gauge
AIR SWITCH
Air Switch Setting .9 ±.05 in. (22.7 ± 1.27 mm) H