A-10 Micro-Tech 9101/9201 Reference Manual, Rev J Thermo Fisher Scientific
3. Press the Partial button and the following screen appears.
4. Press the Edit button and use the keypad to enter the actual length of
the section you marked. (The default value is 200 feet.)
5. Press the Enter button. (We entered 300 feet.)
6. Press the Start button.
BATCH
Ent. len. between
two marks on belt.
Length 200.0 ft
READY
ALARM
CALIB
ABORT
EDIT
BATCH
Ent. len. between
two marks on belt.
Length 300 ft
READY
ALARM
CALIB
ABORT
EDIT
BATCH
Start belt. Press
START when 1
st
mark
passes reference.
READY
ALARM
CALIB
ABORT
START

Table of Contents