You can also set default for “Air-Assist Control” option, so in cut mode,
it will select High volume automatically, and in scan mode (engraving
mode), it will select Low volume automatically.
How to set default for “Air-Assist Control” option?
Go into the RDworks’s root directory>>open the text file of “soft”>>change the setting of
“ShowBlow”>>save the text file, like below.
2) How to adjust air volume if require?
For High volume mode,
1. Make sure machine is not at work and laser switch is off
2. Click the left green button to start the air-assist with high volume
3. Check the air volume under the laser head
4. On left flow control valve, loose the locked nut then rotate the adjusting screw to control
the air volume to mean your requirements.
5. Fix the locked nut after finished.
And for Low volume mode, you do it the same.