5.2 MINIMUM ENCLOSURE CLEARANCES
6”
Non-combustible
floor protection
40” MIN.
1 7/8”
7 1/8”
27” MIN.
3” all around (Refer to vent
manufacturer’s instructions)
2” MIN.
6 3/8”
MIN.
5.3 MINIMUM CLEARANCE TO COMBUSTIBLES
Side wall to appliance 8"
Mantel to top of appliance 8"
Top facing to appliance 6 3/8"
Side facing to appliance 6"
Floor protection* 6"*
8”
MIN
Side Wall
8” MIN
10”
10” Mantel
6”
6”
* Floor Protection: Minimum 6" in front of door
and to either side.