W415-0865 / B / 05.26.11
7
2.2 SPECIFICATIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA C22.1
CANADIAN ELECTRIC CODE (IN CANADA) OR THE ANSI/NFPA NO. 70 NATIONAL ELECTRIC CODE
IN THE UNITED STATES.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE
FRONT FACE OF THE APPLIANCE.
!
WARNING
AB
Adjuistable Flashing 11" to 13" 10 1/2" to 12 1/2"
Electrical Rating 115 Volts, 3.6 Amps, 60Hz
Watts During Ignition Sequence 400 (approximately)
Watts During Operation 180 (approximately)
Weight Stove 158 lbs / Insert 140 lbs
Exhaust Collar 3"
Intake Collar 2"
Hopper Capacity 45 Pounds
EPA Exempt
Burn Rate 1.5 to 4.5 (Pounds Per Hour)
BTU/H 12750 to 38250
Approximate Maximum Heating Capacity (in square feet)* 800 to 2000 Sq. Feet
Maximum Burn Time on Low Burn** 30 Hours
* Heating capacity will vary depending on the home's fl oor plan, degree of insulation, and the outside temperature. It is
also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depend-
ing on fuel quality may occur.
2.3 GENERAL INSTRUCTIONS