Compact IP Codec User's Manual
11
Techno Mathematical Co., Ltd.
2140P
Power ON/OFF
Power ON: After confirming that the rear panel DC power supply is connected,
press the front panel power switch. The power lamp will light. After about 40
seconds the RUN LED (blue) will flash.
Power OFF: Press the front panel power switch. This will turn off power and
cause the power lamp and LEDs to go out.
Operation from a PC
After connecting this device to the setup PC, device operation and setting
configuration can be performed from the setup PC. Download the application
software from the same download site where you downloaded this User's Manual.
Controlling the Device with the Preset Switches
Operations (destination settings, rate control settings, etc.) are assigned to each of
four switches beforehand. TMC can also configure desired settings for you.
Initial default settings are shown in the table below.
Table 3-1 Initial Default Settings of Preset Switches
Switch A Switch B Switch C Switch D
Encoder
Transmission
rate
3Mbps
Transmission
rate
1Mbps
Transmission
rate
128kbps
Rate Control
ON
Decoder
Connection
request to
encoder
192.168.100.101